Setup, Help; Setup, Or (Nudge Keys); K114 Issue No. 9; Druck Adts 405 User Manual - GE Druck ADTS 405 User Manual

Air data test system
Hide thumbs Also See for Druck ADTS 405:
Table of Contents

Advertisement

Druck ADTS 405 User Manual

SETUP, HELP

This function provides help on the set-up key.
SETUP,
or (nudge keys)
This function allows the increment value of the nudge key to be adjusted for every
parameter.
When SETUP,
or
parameter last displayed.
Enter a new value to replace the present value.
Use [NEXT] or [PREV] to display other parameters.
Press CLEAR/QUIT when the nudge values of all the required parameters have been
changed.
In aeronautical units, the parameters available are:
ALT
CAS/TAS
In pressure units, the parameters available are:
Ps
Pt
RATE Ps
-
The nudge value can be used for large increments e.g., 100 kts or 5000 ft to "step
through" the cardinal points of a test.
C
:
M
AUTION
AKE SURE THE NUDGE INCREMENT IS SET TO A SUITABLE VALUE BEFORE USING THE NUDGE
FACILITY TO CHANGE THE AIM VALUE
are pressed, the display shows the value of nudge for the
MACH ROC RATE CAS
Qc
EPR
RATE Qc
RATE EPR
.
6 - 25

K114 Issue No. 9

6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents