2. Preventive Maintenance

2.1 Controller

2.1.1 Inspection plan, Safety Functions

The safety functions of the robots must be tested at least once a year to ensure correct function. The
following tests must be performed.
Test that the Emergency Stop button on the Teach Pendant functions:
o
Press the Emergency Stop button on the Teach Pendant
o
Observe that the robot stops and turns off the power to the joints
o
Power the robot again
Test Free drive mode:
o
Set the robot in Free drive mode by pressing the Free drive button on the Teach Pendant
o
Move the robot to a position where it is stretched out horizontally
o
Monitor that the robot maintains its position when not holding the robot and the Free
drive button still pressed.
Test Back drive mode:
o
If robot is close to collision, the BACKDRIVE function can be used to move robot arm to safe
position before initializing.
o
Press ON to enable power for the joints - Do NOT release the brakes.
o
Press and hold Freedrive -> status will change to BACKDRIVE
o
Pull joint away from collision area -> brake is released for only this joint as long as freedrive
is pressed.
Verify safety settings:
o
Verify that the safety settings of the robot comply with the Risk Assessment of the robot
installation
Test that additional safety inputs and outputs are still functioning:
o
Check which safety inputs and outputs are active and test that they can be triggered.
All rights reserved