Advertisement

13. Settings
ory content is actually deleted, a confirmation window will open; confirming will
clear the storage medium completely; i.e. all files will be deleted.

13.10 About the device

This menu item provides ´Device information´ referring to the individual de-
vice. ´Type´ with number 710 may if appropriate be extended by an option
code. (see Manual 6.10.11) This is followed by the serial number. There are
two different software versions - one for the ´Measuring section´ and one for
the ´User interface´. This is followed by various information, e.g. how to contact
us by telephone or via the Internet.

14. WIZARDS

Some applications depend on such an array of parameters that one or two may
easily be overlooked; some applications need additional calculation processes;
others may need specially adapted menus. With this in mind we have created a
number of ´Wizards´; these can be accessed directly from the ´Home´ screen.

14.1 Data logger

14.2 Scaling
14.3 Two-point sensor adjustment
14.4 Averaging (sliding, over time, over a cycle, over manually selected
individual measuring operations, or over measuring channels)
14.5 Volume flow
14.6 Thermal coefficient
14.7 Wet-bulb globe temperature
14.1 Data logger
The principal task of data logger 710 is data acquisition. To perform this task
and exploit the many possibilities offered by this device you are invited to care-
fully work through these wizards and process all the items requested.
On page 1 we check all the general conditions, e.g. whether date and time-of-
day are set correctly, whether the memory and battery capacity are sufficient,
and whether the correct sensors are connected and functional.
On page 2 we set the conversion rate (see 10.1.1), with which generally all
standard ALMEMO
On page 3 we select the scan cycle (see 10.1.2) for scanning all those mea-
suring channels that provide an updated measured value - either at the conver-
sion rate or, in the case of D7 sensors, according to their own respective actual
measuring duration. All others are omitted. In order to set this important pa-
rameter to best suit the application's needs a number of suggestions reflecting
the properties of the channels in question are listed in a selection box.
The next important decision is whether this scanning rate, very efficiently
adapted to the sensors' requirements, should also be used for saving data to
memory.
66
ALMEMO
sensors operate (V5, DIGI, D6).
®
®