13.2.13 Quantities

Normally, on leaving our factory, all sensor plugs are ready-to-operate. How-
ever, if a measuring range stored in the plug needs to be modified or newly
programmed, the appropriate channel must be selected and, via selection box
´Quantity´, the required range must be programmed. With V5 sensors / con-
nectors the choice is as per the following list. A new measuring channel can
only be activated in ´Sensor settings´  ´Channels, Quantities´. Please note
that with certain sensors a special plug type is required (e.g. thermal, shunt, di-
vider, etc.). When the new measuring range is entered, default units and multi-
plexer are set automatically but all programming values for the channel in
question are deleted. With D7 sensors a separate list of quantities is dis-
played. D6 and D7 sensors can be fully configured in ´Sensor settings´ 
´Sensor configuration´.
Sensor
Pt100-1
ITS90
Pt100-2
ITS90
Pt1000-1
(Element flag 1)
ITS90
Pt1000-2
(Element flag 1)
ITS90
Pt1000-3
ITS90
Ni100
NiCr-Ni (K)
ITS90
NiCr-Ni (K)
++
ITS90
NiCroSil-NiSil (N)
Fe-CuNi (L)
Fe-CuNi (J)
ITS90
Cu-CuNi (U)
Cu-CuNi (T)
ITS90
PtRh10-Pt (S)
ITS90
PtRh13-Pt (R)
ITS90
PtRh30-PtRh6 (B)
Au-FeCr
W5Re-W26Re (C)
Ntc Typ N
Ntc Typ N
++
Ptc Typ Kty84
++
Millivolt 1
Millivolt
Millivolt 2
Sensor / con-
nector
ZA 9000-FS
ZA 9000-FS
ZA 9000-FS
ZA 9000-FS
ZA 9000-FS
ZA 9000-FS
ZA 9020-FS
ZA 9020-SS2
ZA 9020-FS
ITS90
ZA 9021-FSL
ZA 9021-FSJ
ZA 9000-FS
ZA 9021-FST
ZA 9000-FS
ZA 9000-FS
ZA 9000-FS
ITS90
ZA 9000-FS
ZA 9000-SSC
++
ZA 9000-FS
ZA 9040-SS3
ZA 9040-SS4
ZA 9000-FS
ZA 9000-FS
ZA 9000-FS
/h´ from ´mh´, ´W/m
3
Measuring range Units Display
-200.0... +850.0
-200.00...+400.00
-200.0... +850.0
-200.00...+400.00
0.000...+65.000
-60.0... +240.0
-200.0...+1370.0
-100.00...+500.00
-200.0...+1300.0
-200.0... +900.0
-200.0...+1000.0
-200.0... +600.0
-200.0... +400.0
0.0...+1760.0
0.0...+1760.0
+400.0...+1800.0
-270.0...
0.0...+2320.0
-50.00...+125.00
0.000...+45.000
-0.0...+200.0
-26.000...+26.000
-10.000...+55.000
-260.00...+260.00

ALMEMO

Channel functions
from ´Wm´, ´g/kg´
°C
P1O4
°C
P204
°C
P104
°C
P204
°C
P304
N104
°C
°C
NiCr
°C
NiC2
°C
NiSi
°C
FeCo
°C
IrCo
°C
CuCo
°C
CoCo
°C
Pt10
°C
Pt13
°C
EL18
+60.0
°C
AuFe
°C
WR26
°C
Ntc
°C
Ntc3
°C
KTY
mV
mV 1
mV
mV
mV
mV 2
®
710
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents