Restore Program from the USB memory
CAUTION: Memory allocation must be set the same as the saved program. Be sure to
print out the memory allocation so that it can be re-entered before restoring the
program.

Saving Reports to an USB memory

The USB memory can also be used to save reports. Reports saved are the current X1
readings.
USB Report Notes
98 • Service Mode
1. Set the store name to match the name of the store folder you wish to restore.
2. Insert the USB memory in the register's USB port.
3. Move to the SERVICE MODE.
4. From the Service Mode menu, select "7.PROGRAM BACKUP".
5. From the PROGRAM BACKUP menu, select "2.USB".
6. From the USB menu select "2.PGM RESTORE".
7. The register will display confirmation of the successful restore with the message
"SUCCESS !". If the save is unsuccessful, the register will print out an error
message.
1. When backing up and restoring data, the store name must be programmed on
page 133 of "Store Name" in the See "SYSTEM" of "Options Programming".
The default store name is "STORE001".
2. The ER-230EJ will write the program files to folder. For example:
ER-230EJ /STORENAME/SALEBACK/REPBACK/DATE/TIME
The date folder depends on date format option. See "SYSTEM" of "Options
Programming" in the "Program Mode " chapter to set DATE FORMAT.
DATE FORMAT
YYMMDD
DDMMYY
MMDDYY
3. Each individual report is named with the time of the report. For example
"CLK02332" represents a Clerk report taken at 23:32 (in a 24-hour time
format.) In this manner, multiple reports backed up at different times in the
same day will collect in the same "date" folder.
DATE FOLDER NAME
20150403
03042015
04032015