Usb Setting - Sam4s ER-230EJ Operating And Programming Manual

Electronic cash register
Hide thumbs Also See for ER-230EJ:
Table of Contents

Advertisement

Serial Port Settings Screen Program Notes
BAUD RATE
PARITY
DATA BITS
STOP BITS
DEVICE FUNCTION
PRINTER TYPE
DISPLAY
KP START LINE (0-20)
KP END LINE (0-20)
SLIP START LINE (0-20)

USB Setting

Note: If you select other types, Your ER-230EJ will be rebooted by itself.
USB Specifications
PC-COM
SCANNER
MEMORY
82 • Service Mode
Option
1. At the SERVICE MODE, press 5 and CASH for DEFINE PORT.
2. From the DEFINE PORT screen, press 3 and CASH for USB TYPE.
3. Press the ↑ key and the ↓ key to select usb type and press the CASH key to
confirm
DEVICE:
MEMORY
MEMORY
USB TYPE
For connecting PC
For using scanner
For backup & restore
Description
Select 1200, 2400, 4800, 9600, 19200, 38,400,
57,600, or 115,200 from the screen, 9600 is default.
Select NONE, EVEN or ODD, NONE is default.
Select 8 or 7 from the screen, 8 is default.
Select 1 or 2 from the screen, 1 is default.
Select NONE, PC, PRINTER, SCANNER, POLE or
SCALE from the screen, NONE is default.
Select the printer type connected to this port.
Select the pole display type connected to this port.
Enter the number of KP START LINE.
Enter the number of KP END LINE.
Enter the number of SLIP START LINE.
USB VERSION
-
USB 2.0
(only HID type)
USB 2.0
SPEED
-
FULL SPEED
only
FULL SPEED
SAM4S ER-230EJ Manual