Configuration Information For Conveyor Wizard - Siemens Sinamics G120 Operating Instructions Manual

Radio wall transmitters intelligent operator panel
Hide thumbs Also See for Sinamics G120:
Table of Contents

Advertisement

Configuration Information for conveyor wizard

This information allows the user to configure the Inverter for the following applications:
● Roller conveyor with 2 speeds and 2 directions
● Roller conveyor with 2 speeds and 1 direction
● A turntable
Digital connections
The digital inputs are assigned as follows for each application:
Table 4- 1
Roller conveyor (2 directions/2 speeds) and turntable conveyor inputs
Digital input
Function
DI0
Roller conveyor position F
DI2
Roller conveyor position B
DI4
Changeover, fast/slow after F
DI5
Changeover, fast/slow after B
Table 4- 2
Roller conveyor (1 direction/2 speeds) inputs
Digital input
Function
DI0
Roller conveyor position F
DI2
Roller conveyor position B
DI4
Changeover, fast/slow after F
Intelligent Operator Panel (IOP)
Operating Instructions, 03/2013, FW V1.4, A5E00110011A4 AB
Device
Abbreviation
Sensor
-F
Sensor
-B
Sensor
-F/S-F
Sensor
-F/S-B
Device
Abbreviation
Sensor
-F
Sensor
-B
Sensor
-F/S-F
Wizards
4.1 Example wizard