15. Select the macro that is suitable for your application.
16. Set the Minimum Speed at which the attached motor
17. Set the Ramp Up time in seconds.
18. Set the Ramp Down time in seconds.
19. A summary of all the settings is display.
20. The final screen gives two options:
The basic commissioning of your converter is finished.
Intelligent Operator Panel (IOP)
Operating Instructions, 03/2013, FW V1.4, A5E00110011A4 AB
Once selected all inputs, outputs, command sources
and setpoints will be automatically configured by the
software.
For further information see the section that details the
precise settings for each macro. Please see installation
section of this manual.
should run.
This is the time the Inverter/motor system will take from
being given the run command, to reaching the selected
motor speed.
This is the time the Inverter/motor system will take from
being given the OFF1 command, for the motor to reach
a standstill.
If the settings are correct, select Continue.
• Save settings
• Cancel Wizard
If save is selected, a factory reset will be performed then
the settings are saved to the Inverter memory. The
location of safe data is assigned using the "Parameter
saving mode" function in "Parameter settings" in
"Menu".
Wizards
4.1 Example wizard