Siemens 7SK80 Manual page 483

Siprotec motor protection
Hide thumbs Also See for 7SK80:
Table of Contents

Advertisement

No.
Description
5237
81-2 TRIP (81-2 TRIP)
5238
81-3 TRIP (81-3 TRIP)
5239
81-4 TRIP (81-4 TRIP)
6503
>BLOCK 27 undervoltage pro-
tection (>BLOCK 27)
6505
>27-Switch current supervision
ON (>27 I SUPRVSN)
6506
>BLOCK 27-1 Undervoltage pro-
tection (>BLOCK 27-1)
6508
>BLOCK 27-2 Undervoltage pro-
tection (>BLOCK 27-2)
6509
>Failure: Feeder VT
(>FAIL:FEEDER VT)
6510
>Failure: Busbar VT (>FAIL: BUS
VT)
6513
>BLOCK 59 overvoltage protec-
tion (>BLOCK 59)
6530
27 Undervoltage protection
switched OFF (27 OFF)
6531
27 Undervoltage protection is
BLOCKED (27 BLOCKED)
6532
27 Undervoltage protection is
ACTIVE (27 ACTIVE)
6533
27-1 Undervoltage picked up
(27-1 picked up)
6534
27-1 Undervoltage PICKUP
w/curr. superv (27-1 PU CS)
6537
27-2 Undervoltage picked up
(27-2 picked up)
6538
27-2 Undervoltage PICKUP
w/curr. superv (27-2 PU CS)
6539
27-1 Undervoltage TRIP (27-1
TRIP)
6540
27-2 Undervoltage TRIP (27-2
TRIP)
6565
59-Overvoltage protection
switched OFF (59 OFF)
6566
59-Overvoltage protection is
BLOCKED (59 BLOCKED)
6567
59-Overvoltage protection is
ACTIVE (59 ACTIVE)
6568
59-1 Overvoltage V> picked up
(59-1 picked up)
6570
59-1 Overvoltage V> TRIP (59-1
TRIP)
6571
59-2 Overvoltage V>> picked up
(59-2 picked up)
6573
59-2 Overvoltage V>> TRIP (59-2
TRIP)
6801
>BLOCK 48 Motor Startup Time
Supervision (>BLOCK 48)
6805
>48/14 Mot.St.Time Sup. Rotor
locked (>48 Rot. locked)
6811
48 Motor Startup Time Supervi-
sion OFF (48 OFF)
SIPROTEC, 7SK80, Manual
E50417-G1140-C344-A5, Release date 11.2012
Function
Type
of In-
for-
matio
n
81 O/U Freq.
OUT
*
81 O/U Freq.
OUT
*
81 O/U Freq.
OUT
*
27/59 O/U Volt.
SP
*
27/59 O/U Volt.
SP
On
Off
27/59 O/U Volt.
SP
On
Off
27/59 O/U Volt.
SP
On
Off
Measurem.Superv
SP
On
Off
Measurem.Superv
SP
On
Off
27/59 O/U Volt.
SP
*
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
On
Off
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
27/59 O/U Volt.
OUT
*
48/66/51M Motor
SP
*
48/66/51M Motor
SP
*
48/66/51M Motor
OUT
On
Off
Log Buffers
Configurable in Matrix
on
m
LED
on
m
LED
on
m
LED
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED
On
*
LED
Off
*
*
LED
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
On
*
LED
Off
on
m
LED
on
*
LED
*
*
LED
On
*
LED
Off
*
*
LED
On
*
LED
Off
on
m
LED
On
*
LED
Off
on
*
LED
*
*
LED BI
*
*
LED BI
*
*
LED
Appendix
A.9 Information List
IEC 60870-5-103
BO
70
235
2
Yes
BO
70
236
2
Yes
BO
70
237
2
Yes
BO
74
3
1
Yes
BO
74
5
1
Yes
BO
74
6
1
Yes
BO
74
8
1
Yes
BO
74
9
1
Yes
BO
74
10
1
Yes
BO
74
13
1
Yes
BO
74
30
1
Yes
BO
74
31
1
Yes
BO
74
32
1
Yes
BO
74
33
2
Yes
BO
74
34
2
Yes
BO
74
37
2
Yes
BO
74
38
2
Yes
BO
74
39
2
Yes
BO
74
40
2
Yes
BO
74
65
1
Yes
BO
74
66
1
Yes
BO
74
67
1
Yes
BO
74
68
2
Yes
BO
74
70
2
Yes
BO
BO
BO
BO
BO
169
51
1
Yes
483