Siemens 7SK80 Manual page 456

Siprotec motor protection
Hide thumbs Also See for 7SK80:
Table of Contents

Advertisement

Appendix
A.8 Settings
Addr.
Parameter
233
VXnom SECONDARY
235A
ATEX100
238
Ignd2-CT PRIM.
239
Ignd2-CT SEC.
241
Volt.trans.A:C1
242
Volt.trans.A:C2
243
Volt.trans.B:C1
244
Volt.trans.B:C2
245
Volt.trans.C:C1
246
Volt.trans.C:C2
250A
50/51 2-ph prot
251A
CT Connect.
252
Ph LPCT pol.
260
Ir-52
261
OP.CYCLES AT Ir
262
Isc-52
263
OP.CYCLES Isc
264
Ix EXPONENT
265
Cmd.via control
266
T 52 BREAKTIME
267
T 52 OPENING
276
TEMP. UNIT
Holmgr. for Σi
280
302
CHANGE
310
Iph-PRIM ref.
311
Iph-LPCT PRIM
312
Ignd-PRIM ref.
313
Ignd-LPCT PRIM
314
Vph-LPCT SEC
315
Vgnd-LPCT SEC
320A
Corr.factor IL1
321A
Corr.factor IL2
456
Function
C
P.System Data 1
100 .. 225 V
P.System Data 1
NO
YES
P.System Data 1
1 .. 50000 A
P.System Data 1
1A
5A
P.System Data 1
1.0 .. 100.0 pF
P.System Data 1
250 .. 10000 pF
P.System Data 1
1.0 .. 100.0 pF
P.System Data 1
250 .. 10000 pF
P.System Data 1
1.0 .. 100.0 pF
P.System Data 1
250 .. 10000 pF
P.System Data 1
OFF
ON
P.System Data 1
A, B, C, (Gnd)
A,G2,C,G; G->B
A,G2,C,G; G2->B
P.System Data 1
not reversed
reversed
P.System Data 1
10 .. 50000 A
P.System Data 1
100 .. 1000000
P.System Data 1
10 .. 100000 A
P.System Data 1
1 .. 1000
P.System Data 1
1.0 .. 3.0
P.System Data 1
(Setting options depend
on configuration)
P.System Data 1
1 .. 600 ms
P.System Data 1
1 .. 500 ms
P.System Data 1
Celsius
Fahrenheit
P.System Data 1
NO
YES
Change Group
Group A
Group B
Group C
Group D
Binary Input
Protocol
P.System Data 1
10 .. 50000 A
P.System Data 1
1 .. 5000 A
P.System Data 1
1 .. 50000 A
P.System Data 1
0.01 .. 5000.00 A
P.System Data 1
10.0 .. 1000.0 mV
P.System Data 1
10.0 .. 1000.0 mV
P.System Data 1
0.9000 .. 1.1000
P.System Data 1
0.9000 .. 1.1000
Setting Options
Default Setting
100 V
YES
400 A
1A
10.0 pF
2200 pF
10.0 pF
2200 pF
10.0 pF
2200 pF
OFF
A, B, C, (Gnd)
not reversed
125 A
10000
25000 A
50
2.0
None
80 ms
65 ms
Celsius
NO
Group A
400 A
400 A
60 A
2.00 A
225.0 mV
225.0 mV
1.0000
1.0000
E50417-G1140-C344-A5, Release date 11.2012
Comments
Rated Secondary Voltage X
Storage of th. Replicas w/o
Power Supply
Ignd2-CT rated primary c. (conn.
to I2)
Ignd2-CT rated secondary
current (I2)
Voltage transducer A: Capacity
C1
Voltage transducer A: Capacity
C2
Voltage transducer B: Capacity
C1
Voltage transducer B: Capacity
C2
Voltage transducer C: Capacity
C1
Voltage transducer C: Capacity
C2
50, 51 Time Overcurrent with
2ph. prot.
CT Connection
Phase LPCT orientation / polarity
Rated Normal Current (52 Break-
er)
Switching Cycles at Rated
Normal Current
Rated Short-Circuit Breaking
Current
Switch. Cycles at Rated Short-
Cir. Curr.
Exponent for the Ix-Method
52 B.Wear: Open Cmd. via
Control Device
Breaktime (52 Breaker)
Opening Time (52 Breaker)
Unit of temperature measure-
ment
Holmgreen-conn. (for fast sum-i-
monit.)
Change to Another Setting
Group
Primary refer. phase current for
prot.
Rated primary phase current
LPCT
Primary refer. ground current for
prot.
Rated primary ground current
LPCT
Rated secondary phase voltage
LPCT
Rated secondary ground voltage
LPCT
Correction factor for magnitude
IL1
Correction factor for magnitude
IL2
SIPROTEC, 7SK80, Manual