Measured Values; A.11 Measured Values - Siemens 7SK80 Manual

Siprotec motor protection
Hide thumbs Also See for 7SK80:
Table of Contents

Advertisement

A.11

Measured Values

No.
Description
-
Number of TRIPs= (#of TRIPs=)
-
Operating hours greater than (OpHour>)
601
Ia (Ia =)
602
Ib (Ib =)
603
Ic (Ic =)
604
In (In =)
605
I1 (positive sequence) (I1 =)
606
I2 (negative sequence) (I2 =)
621
Va (Va =)
622
Vb (Vb =)
623
Vc (Vc =)
624
Va-b (Va-b=)
625
Vb-c (Vb-c=)
626
Vc-a (Vc-a=)
627
VN (VN =)
629
V1 (positive sequence) (V1 =)
630
V2 (negative sequence) (V2 =)
641
P (active power) (P =)
642
Q (reactive power) (Q =)
644
Frequency (Freq=)
645
S (apparent power) (S =)
661
Threshold of Restart Inhibit (Θ REST. =)
680
Angle Va-Ia (Phi A =)
681
Angle Vb-Ib (Phi B =)
682
Angle Vc-Ic (Phi C =)
701
Resistive ground current in isol systems (INs
Real)
702
Reactive ground current in isol systems (INs
Reac)
805
Temperature of Rotor (Θ Rotor)
807
Thermal Overload (Θ/Θtrip)
809
Time untill release of reclose-blocking (T re-
close=)
830
INs Senstive Ground Fault Current (INs =)
831
3Io (zero sequence) (3Io =)
832
Vo (zero sequence) (Vo =)
833
I1 (positive sequence) Demand (I1 dmd=)
834
Active Power Demand (P dmd =)
835
Reactive Power Demand (Q dmd =)
836
Apparent Power Demand (S dmd =)
837
I A Demand Minimum (IAdmdMin)
838
I A Demand Maximum (IAdmdMax)
839
I B Demand Minimum (IBdmdMin)
SIPROTEC, 7SK80, Manual
E50417-G1140-C344-A5, Release date 11.2012
Function
Statistics
-
-
SetPoint(Stat)
-
-
Measurement
134
157
Measurement
160
145
134
157
Measurement
134
157
Measurement
134
157
Measurement
-
-
Measurement
-
-
Measurement
134
157
Measurement
134
157
Measurement
134
157
Measurement
160
145
134
157
Measurement
134
157
Measurement
134
157
Measurement
134
118
Measurement
-
-
Measurement
-
-
Measurement
134
157
Measurement
134
157
Measurement
134
157
Measurement
-
-
Measurement
-
-
Measurement
-
-
Measurement
-
-
Measurement
-
-
Measurement
134
157
Measurement
134
157
Measurement
-
-
Measurement
-
-
Measurement
-
-
Measurement
134
158
Measurement
-
-
Measurement
134
118
Demand meter
-
-
Demand meter
-
-
Demand meter
-
-
Demand meter
-
-
Min/Max meter
-
-
Min/Max meter
-
-
Min/Max meter
-
-
IEC 60870-5-103
-
-
-
-
-
-
No
9
1
Yes
3
1
No
9
2
No
9
3
No
9
4
-
-
-
-
-
-
No
9
6
No
9
7
No
9
8
Yes
3
2
No
9
9
No
9
10
No
9
11
No
9
1
-
-
-
-
-
-
No
9
12
No
9
13
No
9
5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
No
9
15
No
9
16
-
-
-
-
-
-
-
-
-
No
9
1
-
-
-
No
9
2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Appendix

A.11 Measured Values

Configurable in Matrix
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
CFC
491

Advertisement

Table of Contents
loading

Table of Contents