Siemens 7SK80 Manual page 488

Siprotec motor protection
Hide thumbs Also See for 7SK80:
Table of Contents

Advertisement

Appendix
A.9 Information List
No.
Description
14221
Fail: RTD12 (broken wire/short-
ed) (Fail: RTD12)
14222
RTD12 Temperature stage 1
picked up (RTD12 St.1 p.up)
14223
RTD12 Temperature stage 2
picked up (RTD12 St.2 p.up)
16001
Sum Current Exponentiation Ph
A to Ir^x (ΣI^x A=)
16002
Sum Current Exponentiation Ph
B to Ir^x (ΣI^x B=)
16003
Sum Current Exponentiation Ph
C to Ir^x (ΣI^x C=)
16005
Threshold Sum Curr. Exponent.
exceeded (Threshold ΣI^x>)
16006
Residual Endurance Phase A
(Resid.Endu. A=)
16007
Residual Endurance Phase B
(Resid.Endu. B=)
16008
Residual Endurance Phase C
(Resid.Endu. C=)
16010
Dropped below Threshold CB
Res.Endurance (Thresh.R.En-
du.<)
16011
Number of mechanical Trips
Phase A (mechan.TRIP A=)
16012
Number of mechanical Trips
Phase B (mechan.TRIP B=)
16013
Number of mechanical Trips
Phase C (mechan.TRIP C=)
16014
Sum Squared Current Integral
Phase A (ΣI^2t A=)
16015
Sum Squared Current Integral
Phase B (ΣI^2t B=)
16016
Sum Squared Current Integral
Phase C (ΣI^2t C=)
16018
Threshold Sum Squa. Curr. Int.
exceeded (Thresh. ΣI^2t>)
16019
>52 Breaker Wear Start Criteria
(>52 Wear start)
16020
52 Wear blocked by Time Setting
Failure (52 WearSet.fail)
16027
52 Breaker Wear Logic blk Ir-
CB>=Isc-CB (52WL.blk I PErr)
16028
52 Breaker W.Log.blk
SwCyc.Isc>=SwCyc.Ir (52WL.blk
n PErr)
16029
Sens.gnd.flt. 51Ns BLOCKED
Setting Error (51Ns BLK PaErr)
16030
Angle between 3Vo and INsens.
(ϕ(3Vo,INs) =)
30053
Fault recording is running (Fault
rec. run.)
31000
Q0 operationcounter= (Q0
OpCnt=)
488
Function
Type
of In-
for-
matio
n
RTD-Box
OUT
On
Off
RTD-Box
OUT
On
Off
RTD-Box
OUT
On
Off
Statistics
VI
Statistics
VI
Statistics
VI
SetPoint(Stat)
OUT
On
Off
Statistics
VI
Statistics
VI
Statistics
VI
SetPoint(Stat)
OUT
On
Off
Statistics
VI
Statistics
VI
Statistics
VI
Statistics
VI
Statistics
VI
Statistics
VI
SetPoint(Stat)
OUT
On
Off
P.System Data 2
SP
On
Off
P.System Data 2
OUT
On
Off
P.System Data 2
OUT
On
Off
P.System Data 2
OUT
On
Off
Sens. Gnd Fault
OUT
On
Off
Sens. Gnd Fault
VI
Osc. Fault Rec.
OUT
*
Control Device
VI
*
Log Buffers
Configurable in Matrix
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED BI
*
*
LED
*
*
LED
*
*
LED
*
*
LED
On
Off
*
*
LED
E50417-G1140-C344-A5, Release date 11.2012
IEC 60870-5-103
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
SIPROTEC, 7SK80, Manual