Siemens 7SK80 Manual page 461

Siprotec motor protection
Hide thumbs Also See for 7SK80:
Table of Contents

Advertisement

Addr.
Parameter
1801
50c-2 PICKUP
1802
50c-2 DELAY
1803
50c-1 PICKUP
1804
50c-1 DELAY
1805
51c PICKUP
1806
51c TIME DIAL
1807
51c TIME DIAL
1808
50c-3 PICKUP
1809
50c-3 DELAY
1901
50Nc-2 PICKUP
1902
50Nc-2 DELAY
1903
50Nc-1 PICKUP
1904
50Nc-1 DELAY
1905
51Nc PICKUP
1906
51Nc T-DIAL
1907
51Nc T-DIAL
1908
50Nc-3 PICKUP
1909
50Nc-3 DELAY
2008
67c-3 PICKUP
2009
67c-3 DELAY
2101
67Nc-2 PICKUP
2102
67Nc-2 DELAY
2103
67Nc-1 PICKUP
2104
67Nc-1 DELAY
2105
67Nc-TOC PICKUP
2106
67Nc-TOC T-DIAL
2107
67Nc-TOC T-DIAL
2108
67Nc-3 PICKUP
2109
67Nc-3 DELAY
2201
INRUSH REST.
2202
2nd HARMONIC
2203
CROSS BLOCK
2204
CROSS BLK TIMER
2205
I Max
3101
Sens. Gnd Fault
3102
CT Err. I1
SIPROTEC, 7SK80, Manual
E50417-G1140-C344-A5, Release date 11.2012
Function
C
0.10 .. 35.00 A; ∞
ColdLoadPickup
1A
0.50 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
0.10 .. 35.00 A; ∞
ColdLoadPickup
1A
0.50 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
ColdLoadPickup
1A
0.10 .. 4.00 A
5A
0.50 .. 20.00 A
0.05 .. 3.20 sec; ∞
ColdLoadPickup
0.50 .. 15.00 ; ∞
ColdLoadPickup
1.00 .. 35.00 A; ∞
ColdLoadPickup
1A
5.00 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
0.05 .. 35.00 A; ∞
ColdLoadPickup
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
0.05 .. 35.00 A; ∞
ColdLoadPickup
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
ColdLoadPickup
1A
0.05 .. 4.00 A
5A
0.25 .. 20.00 A
0.05 .. 3.20 sec; ∞
ColdLoadPickup
0.50 .. 15.00 ; ∞
ColdLoadPickup
0.05 .. 35.00 A; ∞
ColdLoadPickup
0.00 .. 60.00 sec; ∞
ColdLoadPickup
1.00 .. 35.00 A; ∞
ColdLoadPickup
1A
5.00 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
0.05 .. 35.00 A; ∞
ColdLoadPickup
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
0.05 .. 35.00 A; ∞
ColdLoadPickup
1A
0.25 .. 175.00 A; ∞
5A
0.00 .. 60.00 sec; ∞
ColdLoadPickup
ColdLoadPickup
1A
0.05 .. 4.00 A
5A
0.25 .. 20.00 A
0.05 .. 3.20 sec; ∞
ColdLoadPickup
0.50 .. 15.00 ; ∞
ColdLoadPickup
0.25 .. 35.00 A; ∞
ColdLoadPickup
0.00 .. 60.00 sec; ∞
ColdLoadPickup
50/51 Overcur.
OFF
ON
50/51 Overcur.
10 .. 45 %
50/51 Overcur.
NO
YES
50/51 Overcur.
0.00 .. 180.00 sec
50/51 Overcur.
1A
0.30 .. 25.00 A
5A
1.50 .. 125.00 A
Sens. Gnd Fault
OFF
ON
ON with GF log
Alarm Only
Sens. Gnd Fault
1A
0.001 .. 1.600 A
5A
0.005 .. 8.000 A
Setting Options
Default Setting
10.00 A
50.00 A
0.00 sec
2.00 A
10.00 A
0.30 sec
1.50 A
7.50 A
0.50 sec
5.00
∞ A
∞ A
0.00 sec
7.00 A
35.00 A
0.00 sec
1.50 A
7.50 A
0.30 sec
1.00 A
5.00 A
0.50 sec
5.00
∞ A
0.00 sec
∞ A
∞ A
0.00 sec
7.00 A
35.00 A
0.00 sec
1.50 A
7.50 A
0.30 sec
1.00 A
5.00 A
0.50 sec
5.00
∞ A
0.00 sec
OFF
15 %
NO
0.00 sec
7.50 A
37.50 A
OFF
0.050 A
0.250 A
Appendix
A.8 Settings
Comments
50c-2 Pickup
50c-2 Time Delay
50c-1 Pickup
50c-1 Time Delay
51c Pickup
51c Time dial
51c Time dial
50c-3 Pickup
50c-3 Time Delay
50Nc-2 Pickup
50Nc-2 Time Delay
50Nc-1 Pickup
50Nc-1 Time Delay
51Nc Pickup
51Nc Time Dial
51Nc Time Dial
50Nc-3 Pickup
50Nc-3 Time Delay
67c-3 Pickup
67c-3 Time Delay
67Nc-2 Pickup
67Nc-2 Time Delay
67Nc-1 Pickup
67Nc-1 Time Delay
67Nc-TOC Pickup
67Nc-TOC Time Dial
67Nc-TOC Time Dial
67Nc-3 Pickup
67Nc-3 Time Delay
Inrush Restraint
2nd. harmonic in % of fundamen-
tal
Cross Block
Cross Block Time
Maximum Current for Inrush Re-
straint
(Sensitive) Ground Fault
Current I1 for CT Angle Error
461