GRAUPNER mc-16 Programming Manual page 308

Hide thumbs Also See for mc-16:
Table of Contents

Advertisement

Phase to:
1 Nor mal
2 Ther mal
to be copied?
NO
YES
Then repeat the process with flight phase "3 Speed".
Now we will program the required settings in the
flight phase "Thermal" as an example.
In order to vary camber flap positions in the «Thermal»
phase, it is merely necessary to switch over to the
menu ...
»Control adjust«
... then change Input 6 – as described beginning on
page beginning on page 112 – from "GL(obal)" to
"PH(ase)" and finally assign it to an operating element.
To do this, first use the selection keys to switch into
the "typ" column for "In6" and change this setting from
"GL" to "PH":
In6
PH
fr
–––
In7
GL
fr
–––
In8
GL
Cn1
–––
In9
GL
–––
8
Thermal
typ
SEL
Thereafter change one column to the right into the
column above SEL ...
308 Programming examples - Using flight phases
In6
In7
In8
In9
Thermal
... and now assign this input, as described in the sec-
tion "Physical control, switch and control switch as-
signments" on page 60, the left proportional slider in
the middle console to, for example:
In6
In7
In8
(page 112)
In9
Thermal
This control will allow the ailerons (2 + 5) and camber
flaps (6 + 7) to be continuously adjusted (as camber
flaps) with a mixer ratio yet to be set via the »Wing
mixers« menu.
0%
If you assign the still free second three-stage switch to
0%
Input 6 instead, you can call three different FL positions
0%
of the ailerons (AIL) and camber changing flaps (FL)
0%
as well as three elevator positions (Elev) in the "Ther-
mal" flight phase, see the following page. (These three
offset
switch positions correspond to the centre position
and the two limit positions of the previously mentioned
proportional rotary control.)
PH
fr
–––
0%
GL
fr
–––
0%
GL
Cn1
–––
0%
GL
–––
8
0%
typ
SEL
offset
PH
Lv1
–––
0%
GL
fr
–––
0%
GL
Cn1
–––
0%
GL
–––
8
0%
typ
SEL
offset
Note:
The FL and AIL flap positions in the two limit
switch positions or in the switch centre
depend on the value set in the column "- trv
+" as well as the offset value and the mixer proportion
set in the "Multi-flap menu" of the »Wing mixers«
menu, see further below.
Leave the (control) "- trv +" at its standard symmetric
settings of +100 % and the offset value at 0 %. Specify-
ing a symmetric or asymmetric time for smooth switch-
ing between the three switch positions – in the example
"1.2 s 1.2 s" – in the column "- time +" is recommended:
In6
1.2s
In7
0.0s
In8
0.0s
In9
0.0s
Thermal
– time +
In the "Multi-flap menu" of the ...
»Wing mixers«
(beginning on page 166)
... menu, subsequently change only the values for "FL.
pos" and "FL" in the «Thermal» flight phase:
FL.pos
It is here that AILE and FLAP positioning takes
place during the «Thermal» flight phase in the event
that the assigned control (proportional control or
3-way switch) is in its neutral or middle position:
1.2s
0.0s
0.0s
0.0s