GRAUPNER mc-16 Programming Manual page 245

Hide thumbs Also See for mc-16:
Table of Contents

Advertisement

This switchover is accomplished by moving the  with
the selection key of the left or right four-way button
until the " " symbol is at the left margin of the bottom
line then tapping on the centre
SET
four-way button:
RX CURVE
V3.78
CURVE1 CH
:
02
TYPE :
CURVE2 CH
:
03
TYPE :
CURVE3 CH
:
04
TYPE :
5CH
FUNCTION:SERVO
Now use one of the  selection keys on the right
four-way button to select the alternative setting "SEN-
SOR".
RX CURVE
V3.78
CURVE1 CH
:
02
TYPE :
CURVE2 CH
:
03
TYPE :
CURVE3 CH
:
04
TYPE :
5CH
FUNCTION:SENSOR
Another tap on the centre
SET
key of the right four-
way button will close the selection and, with appropri-
ate repetitive taps on the centre
ESC
four-way button, a return to the transmitter's basic
display is accomplished.
RX SERVO TEST
The RX SERVO TEST function allows you to test the
servos connected to the currently active receiver:
RX SERVO TEST V3.78
ALL–MAX
: 2000µsec
ALL–MIN
: 1000µsec
TEST
: STOP
ALARM VOLT : 3.8V
ALARM TEMP+: 55°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
Value
Vx.xx
key of the right
ALL-MAX
A
A
ALL-MIN
B
TEST
ALARM
VOLT
A
A
ALARM
TEMP+
B
ALARM
TEMP–
key of the left
CH
OUTPUT
TYPE
ALL-MAX (servo travel on the "+" side)
In this line you set the maximum servo travel on the
plus side of the control travel for the servo test.
2000 μs corresponds to the full throw; 1500 μs corre-
sponds to the neutral position.
Explanation
Possible
settings
Receiver's firmware
None
version
Servo travel on the
1500 ... 2000 µs
"+" side for all servo
outputs for the
servo test
Servo travel on the
1500 ... 1000 µs
"-" side for all servo
outputs for the
servo test
Test procedure
START / STOP
Alarm threshold
3.0 ... 7.5 V
of the receiver
factory setting:
undervoltage
3.8 V
warning
Alarm threshold for
50 ... 80 °C
excessively high
Factory setting:
temperature of the
55 °C
receiver
Alarm threshold
-20 ... +10 °C
for excessively low
Factory setting:
temperature of the
-10 °C
receiver
Channel sequence
ONCE, SAME,
SUMI, SUMO and
SUMD
Make sure that the servos do not overrun mechanically
during the test routine.
ALL-MIN (servo travel on the "-" side)
You adjust the maximum servo travel on the minus side
of the control path for the servo test in this line.
1000 μs corresponds to the full throw; 1500 μs corre-
sponds to the neutral position.
TEST
You start and stop the servo test integrated in the
receivers in this line.
A brief tap on the centre
SET
key of the right four-way
button will open the entry field:
RX SERVO TEST V3.78
ALL–MAX
: 2000µsec
ALL–MIN
: 1000µsec
TEST
:
STOP
ALARM VOLT : 3.8V
ALARM TEMP+: 55°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
Now, with one of the selection keys of the right four-
way button, select START:
RX SERVO TEST V3.78
ALL–MAX
: 2000µsec
ALL–MIN
: 1000µsec
TEST
:
START
ALARM VOLT : 3.8V
ALARM TEMP+: 55°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
A brief tap on the centre
SET
key of the right four-way
button will now start the test run. The input field is
shown as "normal" again:
Program description - Telemetry
245