Lenovo System x3550 M4 Installation And Service Manual page 540

Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

40
CIM Information
Prefix: PLAT ID: 0062
User Response
1. Check the CPU LED. See more information about the CPU LED in Light path diagnostics.
2. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
3. Make sure that the installed microprocessors are compatible with each other.
4. (Trained technician only) Reseat microprocessor n.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number) One of
the CPUs :
806f050c-2001ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 1)
This message is for the use case when an implementation has detected that the Memory Logging Limit
has been Reached.
May also be shown as 806f050c2001ffff or 0x806f050c2001ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Warning - Memory
SNMP Trap ID
43
CIM Information
Prefix: PLAT ID: 0144
User Response
1. Refer to TIP H212293 for minimum code level.
2. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
4. If the error still occurs on the same DIMM, replace the affected DIMM.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
526
System x3550 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents