Lenovo System x3550 M4 Installation And Service Manual page 403

Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

• 80010701-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (PCH Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107012d01ffff or 0x800107012d01ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Reduce the temperature.
2. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
• 80010901-0c01ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted. (Ambient Temp)
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109010c01ffff or 0x800109010c01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
Appendix A. Integrated management module II (IMM2) error messages
389

Advertisement

Table of Contents
loading

Table of Contents