1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
806f090c-200cffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled. (DIMM 12)
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c200cffff or 0x806f090c200cffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
806f090c-200dffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled. (DIMM 13)
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c200dffff or 0x806f090c200dffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
Appendix A. Integrated management module II (IMM2) error messages