User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
• 80010701-0c01ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (Ambient Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107010c01ffff or 0x800107010c01ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Reduce the temperature.
2. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
• 80010701-1001ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (PCI Riser 1 Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011001ffff or 0x800107011001ffff
Severity
Warning
Serviceable
Yes