3. Replace the following components one at a time, in the order shown, restarting the server
each time: a. Hard disk drive. b. Cable from the system board to the backplane. c. Hard disk
drive backplane. (n = hard disk drive number)
806f020d-0406ffff : Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 6)
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0406ffff or 0x806f020d0406ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive b. Cable from the system board to the
backplane.
3. Replace the following components one at a time, in the order shown, restarting the server
each time: a. Hard disk drive. b. Cable from the system board to the backplane. c. Hard disk
drive backplane. (n = hard disk drive number)
806f020d-0407ffff : Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 7)
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0407ffff or 0x806f020d0407ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Appendix A. Integrated management module II (IMM2) error messages