Lenovo System x3550 M4 Installation And Service Manual page 509

Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Refer to TIP H212293 for minimum code level.
2. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
3. Make sure that the DIMMs are firmly seated and no foreign material is found in the DIMM
connector. Then, retry with the same DIMM.
4. If the problem is related to a DIMM, replace the failing DIMM indicated by the error LEDs.
5. If the problem occurs on the same DIMM connector, swap the affected DIMMs (as indicated
by the error LEDs on the system board or the event logs) to a different memory channel or
microprocessor.
6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
7. (Trained service technician only) Remove the affected microprocessor and check the
microprocessor socket pins for any damaged pins. If a damage is found, replace the system
board.
8. (Trained service technician only) If the problem is related to microprocessor socket pins,
replace the system board.
806f030c-200cffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 12)
This message is for the use case when an implementation has detected a Memory Scrub failure.
May also be shown as 806f030c200cffff or 0x806f030c200cffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
Appendix A. Integrated management module II (IMM2) error messages
495

Advertisement

Table of Contents
loading

Table of Contents