Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0850
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Recover the server firmware from the backup page: a. Restart the server. b. At the prompt,
press F3 to recover the firmware.
3. Update the server firmware to the latest level (see Updating the firmware). Important: Some
cluster solutions require specific code levels or coordinated code updates. If the device is part
of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
4. Remove components one at a time, restarting the server each time, to see if the problem
goes away.
5. If the problem remains, (trained service technician) replace the system board.
Firmware Error : Sys Boot Status :
• 806f000f-22010cff : CPU voltage mismatch detected on [ProcessorElementName]. (ABR Status)
This message is for the use case when an implementation has detected a CPU voltage mismatch with the
socket voltage.
May also be shown as 806f000f22010cff or 0x806f000f22010cff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0050
User Response
Appendix A. Integrated management module II (IMM2) error messages