• I.580A6 [I.580A6] Memory spare copy has completed successfully.
Explanation: Spare Copy Complete
Severity
Info
User Response
Complete the following steps:
1. Check system log for related DIMM failures and replace those DIMMs.
• S.1100B [S.1100B] CATERR(IERR) has asserted on processor %.
Explanation: Processor CATERR(IERR) has asserted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
2. (Trained Service technician only) Replace the Processor.
• S.1100C [S.1100C] An uncorrectable error has been detected on processor %.
Explanation: Uncorrectable processor error detected
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reboot system. If problem persists escalate to the next level of supprt.
• S.2011001 [S.2011001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %.
The Vendor ID for the device is % and the Device ID is %.
Explanation: PCI SERR Detected
Severity
Error
User Response
Complete the following steps:
1. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured
Appendix B. UEFI/POST diagnostic codes
799