Example Of Connection; Connecting To Schneider Plc (Modicon Premium Series And Modicon Quantum Series) - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

5.6 Example of Connection

5.6.1
Connecting to SCHNEIDER PLC (Modicon Premium series and Modicon
Quantum series)
System Configuration
SCHNEIDER
Ethernet
PLC
module
Communi
Ethernet
controller
cation
*4
module
Type
Modicon
TSX ETY 4102
Premium
TSX ETY 5102
Series
Ethernet
Modicon
140 NOE 771 00
Quantum
140 NOE 771 10
Series
140 NWM 100 00
*1
Connect the GOT to the Ethernet module via a hub.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
*2
When connecting GT2000 to an equipment that meets the 10BASE (-T/2/5) standard, use the switching hub and operate in an
environment where 10Mbps and 100Mbps can be mixed.
*3
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*4
Product manufactured by SCHNEIDER ELECTRIC SA.For details of the product, contact SCHNEIDER ELECTRIC SA.
*5
Use the straight cable.
PLC Side Setting
POINT
POINT
POINT
SCHNEIDER ELECTRIC PLC
For details of SCHNEIDER PLC, refer to the following manual.
SCHNEIDER PLC user's Manual
Hub
Connection cable
Connection cable
External
Max.
device
*5
Cable model
*3
distance
• 100BASE-TX
Shielded twisted
pair cable (STP)
or unshielded
twisted pair
cable (UTP) of
category 5 or
higher
100m
Hub
• 10BASE-T
Shielded twisted
pair cable (STP)
or unshielded
twisted pair
cable (UTP) of
category 3 or
higher
Connection cable
Connection cable
Max.
*5
Cable model
*3
distance
• 100BASE-TX
Shielded twisted
pair cable (STP)
or unshielded
twisted pair
cable (UTP) of
category 5 or
higher
*1
100m
• 10BASE-T
Shielded twisted
pair cable (STP)
or unshielded
twisted pair
cable (UTP) of
category 3 or
higher
5. MODBUS(R)/TCP CONNECTION

5.6 Example of Connection

Communication driver
MODBUS/TCP
GOT
*2
GOT
Number of
connectable
GOT
Option device
equipment
model
- (Built into
64 GOTs
GOT)
for 1 PLC
5 - 11
5