(b) Monitor screen image
Create the following screens by GT Designer3.
Base screen 1
Sample Screen 1
123
Screen 2
1.
Numerical display
By setting this with the numerical display, the device
value of D21 can be monitored.
The device value is incremented only while [Sample
Screen 1] is displayed.
2.
Switch 1
This is the screen switching switch to [Sample
Screen 2].
Touching this changes the base screen to [Sample
Screen 2].
Base screen 2
Sample Screen 2
Screen 1
3.
Bit lamp
The device status of D22.b0 is displayed as a lamp.
4.
Switch 2
This is an alternate switch for changing the state of
D22.b0.
5.
Switch 3
This is the screen switching switch to [Sample
Screen 1]. Touching this changes the base screen
to [Sample Screen 1].
2 - 76
2. MICROCOMPUTER CONNECTION (SERIAL)
2.7 System Configuration Examples
Numerical display
No.
Device
Data Type
D21
Unsigned BIN16 Signed Decimal
Touch switch
No.
Action
Next Screen
Screen Switching
Fixed
Base
Screen No.2
―
Word
―
BIt
Screen Switching
Fixed
Base
Screen No.1
―
Word
Bit lamp
No.
Lamp Type
Device
BIt
D22.b0
Basic Settings
Device/Style
Format
Number Size
Arbitrary
Basic Settings
Action
Data
Setting
Device
Type
Value
―
―
―
Signed
Constant
D13
BIN16
1
―
―
D22.b0
Alternate
―
―
―
Signed
Constant
D13
BIN16
255
Basic Settings
Device/Style
Shape
Shape Attribute
Arbitrary
Arbitrary
Digits
4
Action
Type
―
―
―
―