3.5 GOT Side Settings

3.5.1
Setting communication
interface (Communication
settings)
Set the channel of the equipment to be connected to the
GOT.
2.
1.
Select [Common]
[Controller Setting] from the
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: Others
• Controller Type: Computer
• I/F: Interface to be used
• Driver: Ethernet (MICROCOMPUTER)
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.

3.5.2 Communication detail settings

Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be set and
confirmed in [I/F Communication Setting]. For details,
refer to the following.
1.1.2 I/F communication setting
Make the settings according to the usage environment.
3.
4.
GOT NET No.
GOT 局番
GOT IP Address
Click!
GOT Communication
Port No.
Startup Time
Delay Time
32bit Storage
Protocol
Format
Interrupt Data Length
Special Interrupt
Output
3. MICROCOMPUTER CONNECTION (ETHERNET)
3.5.2
Communication detail settings
Item
Description
Set the network No. of the
GOT.
(Default: 1)
Set the station No. of the GOT.
(Default: 1)
Set the IP address of the GOT.
(Default: 192.168.3.18)
Set the GOT port No. for the
connection with the Ethernet
module.
(Default: 5021)
Specify the time period from
the GOT startup until GOT
starts the communication with
the PLC CPU.
(Default: 3sec)
Set the delay time for reducing
the load of the network/
destination PLC.
(Default: 0ms)
Select the steps to store two
words (32-bit data).
(Default: LH Order)
Select the communication
*2
protocol
(Default: UDP/IP)
Select the communication
format.
(Default: 1)
Specify the number of bytes of
interrupt data.
(Default: 1)
Set whether or not to output
the special interrupt code.
(Default: none)
3.5 GOT Side Settings
3
Range
1 to 239
1 to 64
0.0.0.0 to
255.255.255.
255
1024 to 5010.
5014 to
65534
(Except for
5011, 5012,
5013 and
49153)
3 to 255sec
0 to 10000
(
10ms)
LH Order/
HL Order
TCP/IP
UDP/IP
1 to 9
1 / 2 / 4
Yes or No