PERFORMANCE
Temperature control range
Temperature distribution
Temperature variation
CO
control range
2
CO
variation
2
O
control range
2
O
variation
2
Chamber humidity
Applicable environment
condition
Noise level
Power consumption
Heat emission
Rated voltage, frequency
Amperage
Note: The unit with CE mark complies with EC directives.
Based on our measuring method.
Designs and specifications are subject to change without notice.
75
MCO-19M
3 trays, 3 sets of tray supports, 3 gas tubes, 1 humidifying pan,
1 gas injection nozzle, 1 gas injection nozzle tube
1 pair of stacking plates A and B, 2 protective stickers, 6 tube bands
H
O
Generator (MCO-HP)
2
2
H
O
Decontamination Kit (MCO-HL)
2
2
UV Lamp Add-on Kit
(MCO-19UVS)
H
O
Decontamination Reagent (MCO-H2O2),
2
2
Automatic CO
Gas Pressure Regulator (MCO-100L),
Extra Trays (MCO-47ST, includes 2 tray supports),
Half Trays (MCO-25ST), Automatic CO
Roller Base (MCO-18RB), UV lamp replacement kit (MCO-20UV)
Stacking spacer (MCO-18SB, when stacking on the MCO-175),
Stacking spacer (MCO-21SB, when stacking on the MCO-20AIC)
Ethernet (LAN) Interface (MTR-L03), RS232C/RS485 Interface (MTR-480)
SANYO Data acquisition software (MTR-5000)
4-20mA Interface (MCO-420MA, USA only)
Ambient temperature+5 to 50
o
± 0.25
C (ambient temperature: 25
o
± 0.1
C (ambient temperature: 25
± 0.15% (ambient temperature: 25
± 0.2% (ambient temperature: 25
Temperature: 5 to 35
(The designed performance may not be obtained
If the ambient temperature is equal or less than 15
Max. 354 W
Max. 1,274 kJ/h
110 to 120 V, 60 Hz
Max. 3.1 A
Multi-gas Incubator
MCO-19M(UV)
Standard equipment
Standard Gas Calibration Kit (MCO-SG),
2
Cylinder Changeover System (MCO-21GC),
2
o
C (ambient temperature: 5 to 35
o
C, setting: 37
o
C, setting: 37
0 to 20%
o
C, setting: 37
1 to 18% and 22 to 80%
o
C, setting: 37
95% ± 5%
o
C, Humidity: 80% max.
30 dB (A scale)
Max. 1,206 kJ/h
220 V, 60 Hz
Max. 1.5 A
- 182 -
MCO-19M(UVH)
Standard equipment
o
C)
o
C, CO
: 5%, O
: 5%, no load)
2
2
o
C, CO
: 5%, O
: 5%, no load)
2
2
o
C, CO
: 5%, O
: 5%, no load)
2
2
o
C, CO
: 5%, O
: 5%, no load)
2
2
o
C)
Max. 335 W
220 to 240 V, 50 Hz
Max. 1.5 A