9.7.3

Setting up the Interface Standard

Set up
The communication protocol for the communication between the projector and a computer can be set on RS232 or RS422. To set
up the desired protocol, handle as follow :
1. Push the cursor key ↑ or ↓ to highlight Interface Standard. (menu 9-18)
The actual interface standard will be displayed.
2. Press ENTER to toggle between RS232 and RS422.
Default : RS232
SERIAL COMMUNICATION
PROJECTOR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 9-18
9.7.4

RS422 Termination

Set up
The last projector in a line should be RS422 terminated (ON position). All others in the line should be in the OFF position. To change
the termination position :
1. Push the cursor key ↑ or ↓ to highlight RS422 Termination. (menu 9-19)
The actual setting will be displayed.
2. Press ENTER to toggle between ON and OFF.
Default : ON
SERIAL COMMUNICATION
PROJECTOR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 9-19

9.8 Network Configuration

DHCP
Dynamic host configuration protocol
What can be done?
The necessary network addresses (configuration) can be entered so that the projector can be connected to a LAN (local area net-
work).