All projectors must have a different projector address between 1 and 12.
All must have the same baud rate and RS mode.
The constant light output setting of one projector must be in the master position. All others must be in the slave position.
Image 9-5
Which information is available
serial number
type
run time
remaining run time
number of strikes
Z-AXIS
How to display the lamp menu
1. Push the cursor key ↑ or ↓ to highlight Lamp. (menu 9-24)
2. Press ENTER to select.
The lamp menu will be displayed. (menu 9-25)
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION
NETWORK
LAMP
MORE...
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 9-24
How to switch the constant light output?
1. Push the cursor key ↑ or ↓ to highlight Constant Light Output.menu 9-25
2. Press ENTER to toggle between [OFF], [SLAVE] and [MASTER].
[OFF]
[SLAVE]
[MAS-
TER]
R5976333 BARCOELM R18 17092002
Downloaded from ProjectorsManual.com Manuals
unique serial number of the lamp
lamp type
total time the lamp is used in this or other projectors.
time left before the lamp must be replaced Using the lamp longer than the maximum run time may
damage the projector.
Total times the lamp is started up.
indication to adjust the Z-AXIS of the lamp (see Re-adjustment of the lamp position in chapter
Installation Guidelines).
LAMP
Constant Light output [OFF]
Mode [NORMAL]
Serial number :
Article number :
Run time :
Remaining run time :
hours
Number of strikes :
Z_AXIS : 100
Select with ↑ or ↓
then <ENTER>
<EXIT> to return.
Menu 9-25
fixed power, no power adaptation.
follows the master projector to adjust the CLO. When stand alone and the light output should be adjusted,
put on slave.
master projector to control the CLO in a chain of projectors.
R101111
R9840xxx
10 hours
490
10
9. Service Mode
95