4. Press ENTER to toggle between the available baudrates.
SERVICE
IDENTIFICATION
PASSWORD
CHANGE PROJECTOR ADDRESS
COMMUNICATION
LAMP
DIMMING
CONVERGENCE
DIAGNOSIS
CLO
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-14
Available baud rates
115200/57600/38400/19200/9600/4800/1200
8.5.2

Serial Interface setting

Set up
1. Push the cursor key ↑ or ↓ to highlight Communication. (menu 8-16)
2. Press ENTER to select.
The communication menu will be displayed. (menu 8-17)
3. Push the cursor key ↑ or ↓ to highlight RS232/RS422.
4. Press ENTER to toggle between RS232 and RS422.
SERVICE
IDENTIFICATION
PASSWORD
CHANGE PROJECTOR ADDRESS
COMMUNICATION
LAMP
DIMMING
CONVERGENCE
DIAGNOSIS
CLO
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-16
8.5.3

RS422 Termination

Set up
The last projector in a line should be RS422 terminated (ON position). All others in the line should be in the OFF position. To change
the termination position:
1. Push the cursor key ↑ or ↓ to highlight RS422 Termination. (menu 8-18)
The actual setting will be displayed.
2. Press ENTER to toggle between ON and OFF.
Default : ON
COMMUNICATION
BAUDRATE [115200]
INTERFACE STANDARD[RS232]
RS422 TERMINATION [OFF]
NETWORK
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-18
R5976690 XLM H25 03/09/2004
COMMUNICATION
BAUDRATE [115200]
INTERFACE STANDARD[RS232]
RS422 TERMINATION [OFF]
NETWORK
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-15
COMMUNICATION
BAUDRATE [115200]
INTERFACE STANDARD[RS232]
RS422 TERMINATION [OFF]
NETWORK
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 8-17