2BC/D

(5) Detaching and refitting the ozone filter

Follow the procedure below to replace the ozone filter.
Procedure
1. Remove the screw holding the conveying duct
cover and then the cover.
2. Remove the two screws holding the middle
rear C cover and then the cover.
3. Replace the ozone filter and refit all the
removed parts.
1-6-14
Middle rear C cover
Middle rear C cover
ozone filter
Conveying duct cover
Figure 1-6-30
ozone filter
Figure 1-6-31