Electrics
Seat Belt Pretensioner
Check the continuity of the line from pretensioner
control module pin 2 to instrument pack green
connector pin 2.
If continuity is approximately OQ, go to step 5.
If the line resistance is significantly greater than OQ,
service the wiring as necessary. Reconnect all
components and test the vehicle to ensure that the
problem is resolved.
Ifthe lamp and wiring checks are good, the fault lies
in the instrument pack or in the control module.
Replace the control module and retest. Ifthe fault
persists, replace the instrument pack. Reconnectall
components and test the vehicle to ensure that the
problem is resolved.
Pretensioner Control Module Internal
Faults
The following codes indicate internal faults within the
pretensioner control module.
0209 Safing sensor error
030A Temperature sensor error
0D13 Capacitor voltage error
0D14 Capacitor capacitance
0D09 Energy reserve switch
0D1E Energy shutdown switch
050E Seatbelt pretensioner switch error
0109 Accelerometer function
01OA Acceleration out of range
01 OB Acceierometer offset
OAOC Analogue voltage error
090A EEPROM not programmed
0909 EEPROM checksum
090C RAM check error
060E Warning lamp driver error
0A09 Communications error
OAOA External watchdog error
OAOB External watchdog time out
020A Safing sensor not closed
If any of the above codes are logged, replace the
pretensioner control module.