The Aston Martin Lagonda Diagnostic System
Installation Instructions
Statement of Calibration
Product Range
Aston Martin Diagnostic System
Product Type
Portable Diagnostic Unit
Product Number
3130-001 7
We certify that the above product has been tested and found to conform to the product specification, priorto dispatch
from GenRad. The measurements performed by this equipment are traceable to international measurement
standards. Calibration records, including the date of calibration and the serial numbers of the measurement
instruments are maintained by GenRad and are traceable through the PDU System serial number.
NOTE: The PDU will not require any periodic adjustment in order to maintain specified measurement accuracy.
Calibration Measurements
Ambient temperature during calibration 20±1 °C.
The test resistances in the table below are applied between the red and black probes. The PDU is set to measure
resistance between these probes using the D M M function. The PDU reading must be between the limits shown.
Test Resistance
10Q
10MQ
PDU Reading Limits
9.84f2-10.16Q
8.22MQ -11.78MQ
The test voltages in the table below are applied between the red and black probes. The PDU is set to measure voltage
between these probes using the D M M function. The PDU reading must be between the limits shown.
Voltage
50mV
lOOmV
160mV
350mV
720mV
1.45V
2.90V
7.25V
14.5V
29V
49V
98V
175V
PDU Reading Limits
48mV - 52mV
98mV - 102mV
157mV - 1 6 3 m V
3 4 5 m V - 3 5 5 m V
7 1 2 m V - 7 2 8 m V
1.43V - 1.47V
2 . 8 6 V - 2 . 9 4 V
7.1 7V - 7.33V
14.35V- 14.65V
2 8 . 7 V - 2 9 . 3 V
4 8 . 5 V - 4 9 . 5 V
9 7 . 0 V - 9 9 . 0 V
173.7V-176.3V
May 1996
9-25