Aston Martin DB7 Workshop Manual page 309

Table of Contents

Advertisement

Air Conditioning
System Fault Diagnosis
D ^
Mode Switch: Low or Medium Temperature Demand Switch: Mid-Range - Function Switch: AC
10 to 12V
0 to SOOmV
2.875 to 2.895V
0 to 500mV
0 to 500mV
0.6 to 0.9V
1.15 to 1.45V
260 to 460mV
4.5 to 5.5V
0 to 500mV
10.3 to 13.3V
10 to 13V
10 to 13V
0 to 0.5V
0 to 0.5V
0 to 500mV
0 to SOOmV
Recirc. input
Recirc. output
Reference voltage
Defrost output
High speed relays
Lower feedback pot.
Upper feedback pot.
Water temp, switch engine cold
Water temp, switch engine hot
Defrost output
Clutch output- evaporator
above 2.745 V
Right hand Blower feedback
Left hand Blower feedback
Right hand Blower control
Left hand Blower control
Water valve solenoid
Centre vent solenoid
9
3
7
11
16
29
30
21
21
11
20
33
22
32
31
17
18
Mode Switch: (Auto) Low Temperature Demand Switch: Minimum
Face Level to mid-range
28
1.43 to 1.45V
Servo Motors Stopped
Servo motor lower flap
37
0 to 40mV
Servo motor lower flap
41
0 to 40mV
Servo motor upper flap
40
0 to 40mV
Servo motor upper flap
42
0 to 40mV
Lower feedback pot.
29
0 to 0.2V
Upper feedback pot.
30
0 to 0.2V
Mode Switch: Low Temperature Demand Switch: Mid-Position - Function Switch: AC
Temperature demand
35
1.43 to 1.45V
Servo Motors Stopped
Servo motor lower flap
37
0 to 40mV
Servo motor lower flap
41
0 to 40mV
Servo motor upper flap
40
0 to 40mV
Servo motor upper flap
42
0 to 40mV
Lower feedback pot.
29
0.57 to 0.87V
Upper feedback pot.
30
0.6 to 0.9V
Mode Switch: Low Temperature Demand Switch: Maximum - Function Switch: AC
Temp demand
35
2.665 to 3.105V
Lower flap feedback pot
29
Upper flap feedback pot.
30
0.979 to 1.279V
1.518 to 1.9V
Mode Switch: (Auto) Face Level: Cold Face
Differential temp.
28
Lower flap feedback pot.
29
Upper flap feedback pot.
30
2.665 to 3.105V
0.979 to 1.279V
1.340 to 1.640V
8-32