Air Conditioning
Temperature Distribution System
Temperature Distribution System
The heating and ventilation unit case consists of three sections:
•
the front, which contains the air conditioning system evaporator
•
the rear section, which consists of two parts and contains the heater matrix and rotary flaps
•
the lower outlets which direct air to footwell and rear passenger compartment and are removable.
Temperature variation within the car is achieved by all incoming air passing through the evaporator and then being
directed through or around the heater matrix by rotary flaps:
•
Full heating (Fig.1)
•
Defrost (Fig. 2)
•
Full cooling (Fig. 3)
Blend (Fig. 4)
Figure 1.
Figure 2.
Figure 3.
Figure 4.
The rotary flaps are opened or closed by servo motors, as directed by the control system, and flap position
information is relayed to the ECM by feedback potentiometers.
(Solid arrow = Hot, Line arrow = Cold)