5.3 Legacy Device Connection
5.3.1 Stacking Connection
Description
KX-TDA600/620, KX-TDE600/620, KX-TDA100D and KX-NS series PBXs can be connected to a KX-NSX
Series PBX via a stacking connection and used to connect telephones, devices, and trunks that are not
natively compatible with the KX-NSX Series. Such items include DPTs and APTs, DSS Consoles, digital
CSs (i.e., non-IP), E1 trunks, and T1 trunks.
A PBX connected through a stacking connection is referred to as a "legacy gateway".
All programming can be done through Web Maintenance Console on the KX-NSX Series.
Conditions
•
Hardware Requirement: STACK-M card (KX-NS1000) and a STACK-S card (for each legacy gateway).
•
The KX-TDA15 and KX-TDA30 are not supported for stacking.
•
The following features are available through a legacy gateway:
–
Parallelled Telephone
–
E1 Line Service
–
T1 Line Service
–
KX-T7710 One-touch Dialling
For details about these features and how to configure the necessary settings, refer to the documentation
of the PBX you will be connecting.
•
IP extensions and trunks, including SIP trunks, are not supported through legacy gateways.
PC Programming Manual References
9.2 PBX Configuration—[1-1] Configuration—Slot—Summary—Legacy Gateway 1 Shelf/Legacy Gateway 2
Shelf
9.28 PBX Configuration—[1-1] Configuration—Slot—Legacy-GW1/Legacy-GW2
10.6.1 PBX Configuration—[2-6-1] System—Numbering Plan—Main—KX-T7710
5.3.2 Trunk Adaptor Connection
Description
IP trunks (V-SIPGW and V-IPGW) can be connected to a Trunk Adaptor (KX-NS8188/KX-NS8290), which
allows the KX-NSX Series to connect to E1 trunks and PRI lines.
Conditions
[General]
•
One IP trunk port corresponds to 1 channel in the Trunk Adaptor.
•
An activation key is not required for ports whose Connection Attribute setting is set to Trunk Adaptor.
Ports without this setting can still be connected to a Trunk Adaptor, but they will require an activation key.
•
One KX-NSX Series can connect to multiple Trunk Adaptors.
•
For details about configuring settings for E1 trunks and PRI lines, refer to the documentation for the Trunk
Adaptor.
[Connection via SIP Trunk]
5.3 Legacy Device Connection
Feature Manual
409