5.3 Legacy Device Connection

5.3.1 Stacking Connection

Description
KX-TDA600/620, KX-TDE600/620, KX-TDA100D and KX-NS series PBXs can be connected to a KX-NSX
Series PBX via a stacking connection and used to connect telephones, devices, and trunks that are not
natively compatible with the KX-NSX Series. Such items include DPTs and APTs, DSS Consoles, digital
CSs (i.e., non-IP), E1 trunks, and T1 trunks.
A PBX connected through a stacking connection is referred to as a "legacy gateway".
All programming can be done through Web Maintenance Console on the KX-NSX Series.
Conditions
Hardware Requirement: STACK-M card (KX-NS1000) and a STACK-S card (for each legacy gateway).
The KX-TDA15 and KX-TDA30 are not supported for stacking.
The following features are available through a legacy gateway:
Parallelled Telephone
E1 Line Service
T1 Line Service
KX-T7710 One-touch Dialling
For details about these features and how to configure the necessary settings, refer to the documentation
of the PBX you will be connecting.
IP extensions and trunks, including SIP trunks, are not supported through legacy gateways.
PC Programming Manual References
9.2 PBX Configuration—[1-1] Configuration—Slot—Summary—Legacy Gateway 1 Shelf/Legacy Gateway 2
Shelf
9.28 PBX Configuration—[1-1] Configuration—Slot—Legacy-GW1/Legacy-GW2
10.6.1 PBX Configuration—[2-6-1] System—Numbering Plan—Main—KX-T7710

5.3.2 Trunk Adaptor Connection

Description
IP trunks (V-SIPGW and V-IPGW) can be connected to a Trunk Adaptor (KX-NS8188/KX-NS8290), which
allows the KX-NSX Series to connect to E1 trunks and PRI lines.
Conditions
[General]
One IP trunk port corresponds to 1 channel in the Trunk Adaptor.
An activation key is not required for ports whose Connection Attribute setting is set to Trunk Adaptor.
Ports without this setting can still be connected to a Trunk Adaptor, but they will require an activation key.
One KX-NSX Series can connect to multiple Trunk Adaptors.
For details about configuring settings for E1 trunks and PRI lines, refer to the documentation for the Trunk
Adaptor.
[Connection via SIP Trunk]
5.3 Legacy Device Connection