3.3 Connection of the FP Web-Server

For an initial function test (without the PLC data), the FP Web-Server has to be connected to the
Ethernet and be supplied with operating voltage (24V DC and FG).
In the second step, the FP Web-Server has to be connected to the PLC (via RS232C). The
RS232C setting of the PLC must correspond to that of the FP Web-Server. This setting can be
defined in the PLC program (FPWIN Pro) under the system parameter settings.
Please remember the ID number found on the FP Web-Server's type label. You
will need it when you configure the Web-Server.