<Limitation of Simplified Isolated Mode operation>
The new features of NSX series such as LDAP directory service are not supported for the EXP-GW.
In addition, the following features are not available in the Simplified Isolated Mode.
Built-in UM (including Auto 2-way recording, 2-way recording, FAX)
CTI Interface (3rd party CSTA)
Built-in ACD monitor/report
System log data such as SMDR, Call Log etc. are not merged with the NSX call server when the
Simplified Isolated Mode is back to Normal Mode. The customised flexible button on the PT
shows the mode status.
If it entered Simplified Isolation Mode by providing the Isolated Mode Notification feature, the
following notification means can notify the state to the user or installer.
1.
Mode indication according to the Networking Status LED
During Simplified Isolated Mode, the Networking Status LED (LED names are KX-NS1000:
Master LED, KX-NS300/KX-NS500/KX-NS700: PBX MODE LED) reports the state of the EXP-
GW to the user.
Modes of the expansion GW
Normal operation status
Simplified Isolated Mode
2.
Mode indication according to the Alarm Key
When transitioning to Simplified Isolated Mode, the Alarm key that was set to FF key of the
IP-PT or the DPT beforehand lights up red, and notifies the operation of Simplified Isolated
Mode to the user.
When the user presses the Alarm key, the Operation Mode will be shown on the telephone's
LCD according to the following table.
Number
1
2
3
Note 1: This is an example, for details see the LCD language data specification.
Note 2: The recover time of the LED of the alarm key is the same as that of conventional Alarm
key.
Note that the relation to the Local Alarm feature (local Alarm) is as follows.
This item is only compatible with the Alarm Key Settings and extensions configured with the
local alarm feature. You can display the operation status by pressing the Alarm Key during
standby.
3.
Error Log and E-mail notification
When transitioning to Simplified Isolated Mode or when releasing Simplified Isolated Mode, it is
possible to store the error information as an error log.
At that time the details can be notified by E-mail.
Conditions
When transitioning between Normal ⇔ Simplified Isolation Mode, accumulated data such as SMDR data
and Call Log data will not be transferred.
Network-Status LED lighting types
Orange light
RED light
System operation mode
Normal operation
Simplified Isolated Mode
Other than 1 and 2
4.2.3 Multi-connection Networking Survivability
LCD when pressing
LED display
down the Alarm Key
OFF
Normal Mode
R-ON
Isolated Mode
OFF
Nothing displayed
Remarks
Remarks