Removal Of Lonizing Wire - Daikin MCK75JVM-K Service Manual

Humidifying air purifier
Hide thumbs Also See for MCK75JVM-K:
Table of Contents

Advertisement

Removal Procedure
8.4

Removal of lonizing Wire

Warning
Step
Undo the 2 hooks and
1
lift the opposing pole
plate to detach.
2
Pinch and detach the
ionizing wires with
pincers.
76
Be sure to wait 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Hook
Hook
Opposing pole plate
Points
The opposing pole plate has
the same shape in 4
directions.
Hook
Hook
(R9807)
(R9808)
Caution
Be careful not to get your hands
cut by the ionizing wires.
Once removed, the ionizing
wires cannot be reused.
When cleaning the ionizing
wires, do not remove them.
(See the Operation Manual.)
(R9809)