Names and Operation of Each Part

Names and Operation of Each Parts
Main unit
Ionizing frame
Pre-filter
Removes large dust particles.
Front panel
Accessories check
Inside box
Operation manual
Inside cushion
Recyclable deodorizing
cartridge
1pc.
Page 23, 24.
7
16
Humidity sensor · Temperature sensor
Filter container
Holds 6 replacement pleated filters.
UNIT2
(Streamer unit)
UNIT1
(Plasma ionizer)
(green)
Ionized wire
Water tank
Small dust particles which are not captured by the pre-filter are positively charged
to that they can be more easily absorbed by the negatively-charged pleated filter.
Odor sensor
Dust sensor
Deodorizing catalyst unit
Absorbs airborne odors and
harmful gases using a deodorizing
catalyst (black), and decomposes
them by streamer action.
Pleated filter
(front: white, back: blue)
Absorbs dust particles using the principle of
static electricity.
Opposing pole plates
(Rear)
(First filter installed)
(First filter installed)
Filter container / Inside box
(Replacement filters)
Pleated filter 7pcs.
• 1pc. (Inside box)
• 6pcs. (Filter container)