Daikin MCK75JVM-K Service Manual page 44

Humidifying air purifier
Hide thumbs Also See for MCK75JVM-K:
Table of Contents

Advertisement

SiBE81-909
UNIT1
(Plasma ionizer)
(1) Ionizing frame
(2) Ionized wire (Rear)
(4) Streamer unit
Open the front panel and pull out the
streamer unit.
Wear rubber
gloves.
Reattach the streamer unit as before.
(2) Ionized wire (8 locations)
• Remove dirt from ionized wires and
surrounding plastic parts with a soft piece
of cloth.
Humidifying Air Purifier
UNIT2
(Streamer unit)
(3) Opposing
pole plates
(4) Streamer unit
UNIT2
Wipe
(For details, see (4)
in the below figure.)
Wear rubber
gloves.
Clean the ionized wires
without dislodging them
from the V-groove.
*Wipe ionized wires gently.
Pulling on them forcefully may
cause them to snap.
CAUTION
There are ionized wires to the rear of the opposing pole plates.
Be careful not to snap these wires when removing and
attaching the units.
• If the unit is run with broken ionized wires, the "UNIT1" lamp
lights. While the lamp is lit, dust collecting capacity is low.
• If the ionized wires are accidentally snapped, they need
replacing, therefore contact the service shop. (Do not
replace the wires yourself.)
• Do not remove the screws from the ionizing frame or streamer unit.
This may lead to damage.
• Clean UNIT1 and UNIT2 somewhere that can be wet such as in a shower
room or kitchen sink.
• For stubborn dirt, soak UNIT1 and UNIT2 in lukewarm or plain water in
which neutral liquid detergent (i.e., kitchen cleaner, etc.) has been
dissolved.
• Use the amount of neutral liquid detergent indicated in the cleaner's
instructions.
• Do not use powdered, alkaline or acidic cleaners, and do not rub with hard
bristle brushes, etc.
Abusive handling may lead to deformation and damage.
• Do not touch the needles inside
Deodorizing capacity diminishes if the needles are deformed.
• If cleaner remains on UNITS 1 or 2, the "UNIT1" and "UNIT2" lamps do not
go out after cleaning, therefore rinse off the cleaner well.
• Do not leave any lint from cleaning cloths behind. Lint may lead to malfunction.
• Plastic parts may deform or discolor if exposed to direct sunlight.
• If water remains on UNITS 1 or 2, even in small quantities, the "UNIT1" and
"UNIT2" lamps do not go out after cleaning, therefore dry thoroughly in a
shade.
(4) Streamer unit
• Remove dirt from plastic parts (
areas with a cotton swab or soft piece of
cloth.
• Do not remove the screws.
Wear rubber
gloves.
Cotton
swab
Operation Manual
Notes
(streamer unit).
UNIT2
) in internal
Do not touch
the needles.
*Do not touch the needles (2 locations).
Deodorizing capacity diminishes if the
needles are deformed.
: Plastic parts
34
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents