Removal Procedure
9.3

Removal of Ionized Wire

Procedure
Step
Unfasten the 2 hooks
1
and lift the opposing
pole plate to detach.
Pinch and detach the
2
ionized wires with
pincers.
Remove the 3 screws
3
and remove the ionized
wire mounting frame
and contact switch.
Remove the 3 screws
4
and remove the contact
switch for ionized wire.
46
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Hook
Opposing
pole plate
Contact switch
for ionized wire
(R12351)
(R12352)
Ionized wire
(R12353)
Ionized wire
mounting frame
Contact switch
SiBE811120
Points
The opposing pole plate has
the same shape in 4
directions.
Caution
Be careful not to get your hands
cut by the ionized wires.
Once removed, the ionized
wires cannot be reused.
When cleaning the ionized
wires, do not remove them.
(Refer to the Operation
Manual.)
(R12354)
Photocatalytic Air Purifier L-Series