Daikin MCK75JVM-K Service Manual page 55

Humidifying air purifier
Hide thumbs Also See for MCK75JVM-K:
Table of Contents

Advertisement

Troubleshooting
If this happens
Crackling, buzzing,
and fizzes sounds
are audible during
operation.
Odor is coming from
the air outlet.
The "UNIT1" lamp
does not go out or
immediately lights
again, despite having
cleaned that UNIT1
(plasma ionizer).
Humidity does not rise.
If the problem cannot be corrected after taking the above action, contact the service shop.
54
Check
Is the UNIT1 set securely?
Has dust accumulated on the ionized
wires of the ionizing frame?
A hissing sound heard from UNIT2 during
operation. There is nothing wrong with the unit.
Is a large amount of odor being generated
temporarily? (Many people smoking or grilling meat.)
Have you moved the main unit to another room?
Are the pre-filter, pleated filter, UNIT1 and/or
humidifying filter dirty?
Are odors constantly being generated in the
room (i.e., paint, new furniture, wall paper,
sprays, cosmetics, chemicals, etc.)?
Is the UNIT1 set securely?
Are not droplets left in the opposing pole plates
or other places?
Are not bits of lint left in the UNIT1?
Was UNIT1 inadequately rinsed after cleaning
with a cleaner?
Are not the ionized wires cut?
Is the room too big?
Is indoor temperature low with the walls and
floor dry?
Is air flow set to a low rate?
How to resolve
Securely set it.
Page 18.
Clean it.
Page 33, 34.
If operated, the odor will gradually go away.
Odor from the original room may smell.
Let the unit run for a while.
Clean it.
Page 29~36.
Ventilate the room or let the unit run
with air flow promoted in the room.
Securely set it.
Page 18.
Completely dry UNIT1 after cleaning it.
Remove all lint.
Remove any remaining cleaner.
Page 33, 34.
Check the ionized wires.
Page 34.
If broken, they need replacing, therefore contact
the service shop.
Use the unit in an appropriately sized room.
Humidity does not readily rise if the indoor temperature
is low, and the walls and floor are dry. Watch the
situation for 1 - 2 weeks to see if humidity rises.
Set "CONT" for the humidify setting and increase
the air flow rate setting.