Removal Procedure
Step
7
Open the operation
sign cover.
2. Removal of the
operation PCB
1
Disconnect the linkage
connector from the
power supply / control
PCB.
Remove the 2 screws.
2
3
Release the 8 hooks.
Remove the operation
PCB.
80
Procedure
Wire harness for dust sensor
Insert the wire harness
(for display) horizontally.
Linkage
connector
[S1]
[S3]
[S128]
Hooks
Hooks
Operation PCB
(R9769)
(R9815)
[S1] : Dust sensor
[S3] : Humidity sensor
[S128] : Connector for power
[S129] : Connector for display
(R9816)
[S129]
(R9817)
SiBE81-909
Points
Be careful as the linkage
connector is connected.
When assembling, wire
harness shall be inserted
securely. Do not insert it
aslant.
Insert the linkage connector
until the silver part cannot be
found.