Removal Of Proximity Switch - Daikin MCK75JVM-K Service Manual

Humidifying air purifier
Hide thumbs Also See for MCK75JVM-K:
Table of Contents

Advertisement

SiBE81-909
8.9

Removal of Proximity Switch

Warning
Step
1. Removal of the
proximity switch
Remove the screw and
1
remove the drip-proof
plate.
2
Remove the screw and
remove the proximity
sensor.
3
Disconnect the
connector of the limit
switch [S115].
Humidifying Air Purifier
Be sure to wait 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Proximity sensor
In case of OFF
Proximity
sensor
When assembling
insert the harness
into the slit.
Drip-proof
plate
(R9842)
In case of ON
(R9843)
[S115]
Limit
switch
Holding plate
(R9844)
Removal Procedure
Points
91