Daikin MCK75JVM-K Service Manual page 87

Humidifying air purifier
Hide thumbs Also See for MCK75JVM-K:
Table of Contents

Advertisement

Removal Procedure
Step
4
Remove the 2 fixing
screws.
5
Pull and lift up the
upper part of the power
supply / control PCB,
and undo the 2 hooks.
Then remove the PCB.
The figure shows the
6
power supply / control
PCB.
86
Procedure
Power supply /
control PCB
Hooks
[S116]
[S102]
[FU1(F1U)]
Fuse
[S108]
250V 3.15A
(R9828)
(R9829)
[S102] : Fan motor
[S113] [S115] [S114]
[S108] : Safety switch
[S113] : Float (proximity sensor)
[S114] : Limit switch
[S115] : Limit switch (tray)
[S116] : Motor for the
[S118] : Connector for the
[S118]
(R9830)
SiBE81-909
Points
switch
(regeneration of
cartridge)
humidifying rotor
operation PCB [S128]
Humidifying Air Purifier

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents