Step
3. Removal of the high
voltage PCB
1
Disconnect the 3
harnesses (for
electrostatic earth :
green, red, white).
2
Disconnect the harness
(for dust collection :
green).
Remove the high
voltage PCB by
releasing the 2 hooks
and removing the 1
screw.
The figure shows the
3
high voltage PCB.
Humidifying Air Purifier
Procedure
a
Hooks
Green
a
(R9831)
b
c
d
(R9832)
Red
c
b
d
(R9833)
Removal Procedure
Points
Hook
Zoomed up view of the
terminal.
Disconnect the terminals by
pushing the hook.
a 1Harness (for electrostatic earth)
b 2Harness (red)
}
for high voltage
c 3Harness (white)
d 4Harness (for dust collection)