Cold Start: X1 Outdoor; Table 4. Evolution X1 Outdoor Warm-Up Periods - iDirect evolution x1 Installation Manual

Satellite routers
Table of Contents

Advertisement

8.4

Cold Start: X1 Outdoor

An Evolution X1 Outdoor Satellite Router is designed to operate in ambient temperatures as
o
low as -40
C. However, if the Satellite Router is without power long enough for the internal
temperature to fall below -25
The warm-up period for the X1 Outdoor Satellite Router depends on the internal modem
temperature measured at the time power is restored. The warm-up periods are defined in
Table
4.
During the warm-up period, a Web iSite connection to the Evolution X1 Outdoor Satellite
Router can be established using a Web browser. Although the X1 Outdoor has only one physical
LED indicating power, four LED-like indicators on the X1 Web iSite pages show the current
state of the Satellite Router. During warm up, the LEDs display the following colors:
Receive: Yellow
Network: Yellow
Transmit: Yellow
Power:
Using Web iSite, observe the Evolution X1 Dashboard
up period. On the Dashboard:
The Temperature field increases as the modem warms up.
The Satellite Rx field shows Waiting for Demod Lock.
Once warm-up is complete, the Web iSite status indicators show the same status as the
Evolution X1 Indoor Satellite Router LEDs. See
iDirect Satellite Router Installation and Commissioning Guide
iDX Release 3.3
o
C, a warm-up period is required before becoming operational.

Table 4. Evolution X1 Outdoor Warm-Up Periods

Internal Modem Temperature
o
-25
C to -35
o
-35
C to -40
Green
Warm-Up Period
o
C
1.5 minutes
o
C
4.0 minutes
(Figure 29
Table 9
on
page 96
Connecting with Web iSite
on
page
48) during the warm-
for details.