Setting Power
7. If the procedure
performed:
a. Click the Remote Custom tab.
b. Enter the following Remote-Side custom key:
[UCP]
max_power_level_in_db_pn = <Modulated Max Power>
where <Modulated Max Power> is the maximum power determined in
Procedure to Determine PN Max Power" on
8. Click OK to save the changes.
9. Right-click the remote in the iBuilder Tree and select Apply Configuration
(TCP).
If commissioning a remote in a TRANSEC network and authentication has been disabled,
perform the following steps:
1. If the remote has not yet been issued an X.509 certificate, issue the certificate now. (See
the iBuilder User Guide appendix "Using the iDirect CA Foundry" for details.)
2. Re-enable authentication on the remote Information tab by clearing the Disable
Authentication check box.
3. Click OK to save the changes.
4. Right-click the remote in the iBuilder Tree and select Apply Configuration
(TCP).
102
"Optional Procedure to Determine PN Max Power" on page 88
Figure 56. Setting Modulated Maximum Power Custom Key
iDirect Satellite Router Installation and Commissioning Guide
page 88. This is illustrated in
was
"Optional
Figure
56.
Reliable Both
Reliable Both
iDX Release 3.3