CP2215 User Manual
020-101225-01 Rev. 1 (01-2014)
Downloaded from ProjectorsManual.com Manuals
• SOFTST - (Software State) Indicates the state of the software application running on the
ICP. During normal operation, this LED blinks. During start up, the LED changes from off to
blinking.
• OSST - (Operating System State) Indicates the state of the ICP operating system. During
normal operation, the LED is green. During start up, the LED changes from off to green.
• FMTST - (FMT FPGA State) Indicates the state of the FMT FPGA. During normal operation,
the LED is green. When the power is turned on, the LED turns green immediately.
• ICPST - (ICP FPGA State) Indicates the configured state of the ICP FPGA. During normal
operation, the LED is green. When the power is turned on, the LED turns green
immediately.
• PORT B - Indicates the status of the USB port. A green LED indicates the port is active. If
the LED is not illuminated, the port is inactive.
• PORT A - Indicates the status of the USB port. A green LED indicates the port is active. If
the LED is not illuminated, the port is inactive.
Indicates the status of the Integrated Cinema Processor (ICP). A green LED indicates the ICP
is operating correctly. A red LED indicates a communication issue. If the LED is not
illuminated, the ICP is inactive.
• STBY - The LED is green when the standby power supply is active. If the LED is not
illuminated, the standby power supply has failed or the projector circuit breaker is off.
• PWR - The LED is green when the Low Voltage Power Supply (LVPS) is active. If the LED is
not illuminated, the LVPS has failed or the projector circuit breaker is off.
• RUN - The LED flashes green when the projector is operating normally. If the LED is not
illuminated or solid green, a communication, software, or hardware error has occurred. If
the LED is yellow, the projector cannot communicate with the touch panel controller (TPC).
• PIB - The LED is green when the Projector Intelligence Board (PIB) is detected and
operating correctly. A red LED indicates a communication error. A flashing red LED indicates
the PIB is not installed correctly. If the LED is not illuminated, the PIB is inactive.
• ICP - The LED is green when the ICP is operating correctly. A red LED indicates a
communication issue. If the LED is not illuminated, the ICP is inactive.
• LD - The LED is green when the Link Decrypter (LD) is active.
• IMB - The LED is green when the Integrated Media Block (IMB) is operating correctly. A red
LED indicates a communication issue. If the LED is not illuminated, the IMB is inactive.
Indicates marriage status. In full power mode, a green LED indicates that the projector is
properly married and encrypted content can be displayed. A red LED indicates marriage is
broken and encrypted content cannot be displayed.
Turns the projector and the lamp on and opens the douser. Press and hold the button to close
the douser, turn the lamp off, and keep the power on. It is recommended that you use this
button only when the TPC is unavailable.
Resets the projector electronics. After restarting, the projector returns to its previous power
mode. You must strike the lamp manually.
Connects the projector to 3D devices such as MasterImage or RealD.
A Simple Contact Closure Interface (SCCI) port that uses a simple dry contact closure to turn
the lamp on or off or open or close the douser.
Connects the projector to a computer.
Connects the projector to Christie or third-party automation equipment. Utilizes the Christie-
proprietary protocol.
Connects the projector to a 10Base-T/100Base-TX Ethernet connection.
Installation and Setup